HVAC Package | Available in: UK & EU

All-in-One Pump Package for High-Humidity Spaces – Save Time with A Pre-Specified Condensate removal system

Designed to save time, the MaxiBlue® Pro package is a high-performance pre-specified solution designed for efficient and reliable condensate removal for air conditioning systems. Featuring advanced thermistor technology, pump offers quiet operation, self-priming capability, and energy-efficient performance, making it ideal for mid-range AC units in commercial and residential settings. The MaxiBlue® Pro can be installed in various orientations, ensuring flexibility even in challenging locations. Whether used in offices, hotels, or ceiling-mounted units, this pump delivers powerful, low maintenance operation while minimising downtime and disruption. All elements in this kit are fully compatible and specified to the correct sizes – saving time in sourcing multiple elements for your condensate removal system.

Key Features

• Ultra-quiet in operation – 21dB(A)
• Mid-range condensate pump merging size and performance into one
• Self-priming activation, no need for siphoning devices
• Unique patented Rotary Diaphragm technology
• Plug and play set-up for quick installation
• Small and compact body
• Pre-specified package ensures all parts a compatible and the correct sizes

Application

• Air conditioning systems up to 14KW
• Mini-Split
• Cassette systems
• Mid-range fan coil applications
• Ideal for large office blocks
• Conference rooms
• Retail and commercial areas
• High-humidity environments

PurchaseD With

MaxiBlue® (FSA) -condensate removal pump (x1)
• Reservoir (Thermistor sensing technology) (x1)
• Rubber mounting foot (x2)
• Flexible stepped adapter (x1)

24M long braided tubing (6.3mm ID) (x1)
• Drain pipe adapter (x1)
• Unex hose clip (x2)

CHANGE MEASUREMENT
METRIC
IMPERIAL
Performance

Max Flow:

14 L/Hour

Max Head:

8 Metres

Max Lift:

8 Metres

Volume:

21 dB(A)

UNIT

Max A/C KW:

8.0 -14.0 KW

Consumption

Voltage:

240V

Frequency:

50Hz

Draw (A):

0.03 (115V), 0.06 (240V)

Power (W):

5.5W

Power (VA):

5.7VA

Power Factor:

0.96

IP Rating:

IPX4

Sizing

Dimensions:

138 x 58 x 67mm

Weight:

663g

Inlet:

8mm Barbed

Outlet:

8mm Barbed

Alarm Lead:

2 Metre

Reservoir:

90 x 40 x 30mm

Discharge tubing:

24M (6.3mm ID)

Performance

Max Flow:

2.11 G/Hour

Max Head:

23 Feet

Max Lift:

16.5 Feet

Volume:

21 dB(A)

UNIT

Max A/C BTU:

48000 BTU

Consumption

Voltage:

110 - 120V

Frequency:

50/60Hz

Draw (A):

0.13 (115V), 0.06 (240V)

Power (W):

5.5W

Power (VA):

14.4VA

Power Factor:

0.35

IP Rating:

IPX4

Sizing

Dimensions:

5.43 x 2.28 x 2.65 Inches

Weight:

23.3 oz

Inlet:

1/4 Inch Barbed

Outlet:

1/4 Inch Barbed

Power Lead:

6.5 Feet

Reservoir:

3.5 x 1.5 x 1.2 Inches

Discharge tubing:

78 Feet (1/4 Inch ID)

TESTED performance

Rigorously tested by our in-house R&D team, every Maxiblue pump undergoes thorough performance and endurance testing before leaving our manufacturing facilities, ensuring consistent, reliable operation in the field.

Regularly trusted by engineers worldwide, the MaxiBlue has earned a reputation for durability and reliability, significantly reducing the need for call-outs and regular maintenance.

TESTED performance

Rigorously tested by our in-house R&D team, every MaxiBlue pump undergoes thorough performance and endurance testing before leaving our manufacturing facilities, ensuring consistent, reliable operation in the field.

Regularly trusted by engineers worldwide, the MaxiBlue has earned a reputation for durability and reliability, significantly reducing the need for call-outs and regular maintenance.

Discharge Pipe

Vertical (V):

Horizontal (H):

8 Metres

0 Metres

7 Metres

3 Metres

6 Metres

6 Metres

5 Metres

9 Metres

4 Metres

12 Metres

3 Metres

15 Metres

2 Metres

18 Metres

1 Metres

21 Metres

Unit Size

Max KW Unit:

14KW

Unit Type:

Mini split

Note: The MaxiBlue® can be mounted in any orientation up to 8 Metres away from the air-conditioning unit. We recommend mounting the pump inside the ceiling cavity or ducting kit for a discreet fit.

Discharge Pipe

Vertical (V):

Horizontal (H):

25 Feet

0 Feet

22 Feet

9 Feet

20 Feet

20 Feet

16 Feet

30 Feet

13 Feet

40 Feet

9 Feet

50 Feet

6 Feet

60 Feet

3 Feet

70 Feet

Unit Size

Max KW Unit:

18000 BTU

Unit Type:

Mini split

Note: The MaxiBlue® can be mounted in any orientation up to 25 Feet away from the air-conditioning unit. We recommend mounting the pump inside the ceiling cavity or ducting kit for a discreet fit.

Pump purchasing options Part No. Available in
MaxiBLUE® + (FSA) PRO PACKAGE X87-707    UK, EU, ROW
Altnernative Pump purchasing options Part No. Available in
MaxiBLUE® + RESERVOIR (FSA) X87-701    UK, EU, ROW
MaxiBLUE® + DRAINSTIK® SENSOR X87-702    UK, EU, ROW
MaxiBLUE® + TEMPERATURE SENSOR X87-703    UK, EU, ROW
MaxiBLUE® + RESERVOIR (FSA) (115V) X87-711    Americas
MaxiBLUE® + DRAINSTIK® (FSA) (115V) X87-721    Americas
MaxiBLUE® + RESERVOIR (FSA) (208V - 230V) X87-722    Americas
MaxiBLUE® + DRAINSTIK® (FSA) (208V - 230V) X87-722    Americas
MaxiBLUE® + TEMPERATURE SENSOR (115V) X87-713    Americas
MaxiBLUE® + TEMPERATURE SENSOR (208V - 230V) X87-723    Americas
Alarm differences

FSA– Fail safe alarm, a volt free relay designed to switch the AC unit off, but leaves the pump running continuously when the condensate reaches a critical point in the reservoir.

HLA– High Level Audio is an integral audio and visual alarm. When the condensate is at a critical point with-in the reservoir, the diagnostic light in the pump will switch from green and will start to flash red with a 2 beep warning every minute. The pump will continue to operate while in alarm mode.

This mark indicates that our motors comply with UK regulations and meet the required health, safety, and environmental protection standards for products sold in Great Britain (England, Scotland, and Wales). For details, visit our compliance website here.

This mark signifies that our motors comply with CE requirements, confirming they meet essential health, safety, and environmental protection standards for products sold within the European Economic Area (EEA). For more information, visit our compliance website here.

Plenum spaces circulate air in buildings, often for HVAC systems. “Plenum-rated” materials limit smoke and toxic fumes in a fire, helping prevent their spread through the building. Visit compliance website here.

This mark indicates that our motors have been tested and meets safety standards in both the United States (UR) and Canada (cUR)Visit compliance website here.

Unique features

PUMPS BIOFILMS & DEBRIS WITH EASE

Utilising the power of our patented rotary diaphragm technology, the MaxiBlue pump efficiently removes condensate, preventing biofilm build-up and ensuring smooth, uninterrupted drainage. Its powerful pumping action effectively clears debris and minimises blockages, reducing maintenance requirements and lowering the risk of system failure and biofilm build-up in the system.

RELIABLE RESERVOIR SENSOR

Remove the hassle of stuck float switches. Our advanced thermistor-based sensing technology detects temperature variations to accurately determine the presence of condensate in the reservoir. By responding to changes in thermal conductivity caused by condensate from the air conditioning unit, it offers superior sensitivity, durability, and reliability compared to traditional, old fashioned float switches.

FLEXIBLE INSTALLATION

The MaxiBlue pump offers flexible installation with the ability to be mounted in any orientation without affecting performance (8m/ 23ft away from the unit). Its versatile mounting options allow for seamless integration into tight spaces or unconventional setups, ensuring reliable operation across a wide range of applications.

TRUSTED RELIABILITY

The MaxiBlue® was the first in its class to come with a market leading 3-year warranty—proof of the confidence we have in its patented, ultra-reliable pumping technology.

Every MaxiBlue® pump is precision-engineered and rigorously tested at our state of the art manufacturing facility meeting or exceed ISO9001 standards. From material selection to final inspection, quality is built into every step.

Rotary Diaphragm Technology EXPLAINED

VALVELESS TECHNOLOGY

Rotary diaphragm technology uses a flexible rotating diaphragm to move fluids, removing the need for valves. Its anti-clogging design reduces wear and maintenance, while improving reliability—especially when dealing with debris-laden condensate. The exclusive technology delivers a consistent, powerful flow and is fully self-priming, making it ideal for high-lift applications.

Related Products

Max Flow:8 L/MIN (2.1 G/HOUR)
Max Head:8 M (26 FT)
Max Lift:5 M (16FT)
Sound:21 dB(A)
Unit:3.5 – 8.0 KW (18000 BTU)

AVAILABLE IN: UK, EU &

MINIBLUE

Max Flow:8 L/HOUR (2.1 G/HOUR)
Max Head:8 M (26 FT)
Max Lift:5 M (16FT)
Sound:21 dB(A)
Unit:3.5 – 8.0 KW (18000 BTU)

Available in UK & EU

MAXIBLUE

Max Flow:14 L/HOUR (3.7 G/HOUR)
Max Head:8 M (23 FT)
Max Lift:8 M (16.5FT)
Sound:21 dB(A)
Unit:8.0 – 14 KW (48000 BTU)

Available in UK, EU & USA

MULTITANK

Compatibility:MaxiBlue, MegaBlue
Sensor type:Thermistor Sensing
Dimension:355 x 127 x 105mm (13.9 x5 x 4.1″)
Tank Capacity:1.5 Litres ( 0.4 Gallons)
Ideal for:Multi-system installation

Available in UK, EU & USA