Compact, ultra-quiet condensate removal PUMP - built for reliability and performance
The MicroBlue® condensate removal pump features advanced dynamic diaphragm control and leads the microsized condensate pump market with superior performance. Its compact, anti-vibration design is ideal for conduit and discreet installations, delivering reliable, self-priming flow even in demanding high-lift applications. With dual voltage capability and a 3-year warranty, the MicroBlue sets a new benchmark for reliability and efficiency.
Key Features
• Ultra-quiet in operation – 17dB(A)
• Anti-vibration design and rubber mounts
• Self-priming activation, no need for siphoning devices
• Unique patented GyRok™ technology
• Plug and play set-up for quick installation
• Small, compact and lightweight
Application
• Mini-Split systems up to 3.5KW
• Ideal for bedrooms
• Small offices
• Libraries
• Areas where sound suppression is a priority
PurchaseD With
• Reservoir (CondenSense™ technology)
• Ducting kit (Ivory) + CondenSense™ Reservoir (UK/EU)
• Ducting kit (White) + CondenSense™ Reservoir (UK/EU)
• Slim fascia kit (USA Only)
Performance
Max Flow:
5 L/Hour
Max Head:
5 Metres
Max Lift:
2 Metres
Volume:
17 dB(A)
UNIT
Max A/C KW:
3.5 KW
Consumption
Voltage:
110 - 240V
Frequency:
50 / 60 Hz
Draw (A):
0.13 (115V), 0.06 (240V)
Power (W):
5W
Power (VA):
14.4VA
Power Factor:
0.35
IP Rating:
IPX4
Sizing
Dimensions:
150 x 37 x 40mm
Weight:
226g
Inlet:
6mm Barbed
Outlet:
6mm Barbed
Alarm Lead:
0.5 Metres
Ducting Kit:
930 x 140 x 75mm
Reservoir:
102 x 31 x 38mm
Performance
Max Flow:
1.3 Gal/Hour
Max Head:
16.4 Feet
Max Lift:
6.5 Feet
Volume:
17 dB(A)
UNIT
Max A/C BTU:
180000 BTU
Consumption
Voltage:
110 - 240 V
Frequency:
50/60Hz
Draw (A):
0.13 (115V), 0.06 (240V)
Power (W):
5W
Power (VA):
14.4VA
Power Factor:
0.35
IP Rating:
IPX4
Sizing
Dimensions:
5.9 x 1.46 x 1.57 Inches
Weight:
7.9 oz
Inlet:
0.2 Inch Barbed
Outlet:
0.2 Inch Barbed
Alarm Lead:
1.6 Feet
Ducting Kit:
36.6 x 5.5 x 2.95 Inches
Reservoir:
4.0 x 1.25 x 1.49 Inches
Tested performance
Rigorously tested by our in-house R&D team, every Microblue pump undergoes thorough performance and endurance testing before leaving our manufacturing facilities, ensuring consistent, reliable operation in the field.
Regularly trusted by engineers worldwide, the Microblue has earned a reputation for durability and reliability, significantly reducing the need for call-outs and regular maintenance.
TESTED PERFORMANCE
Rigorously tested by our in-house R&D team, every Microblue pump undergoes thorough performance and endurance testing before leaving our manufacturing facilities, ensuring consistent, reliable operation in the field.
Regularly trusted by engineers worldwide, the Microblue has earned a reputation for durability and reliability, significantly reducing the need for call-outs and regular maintenance.
Discharge Pipe
Vertical (V):
Horizontal (H):
5 Metres
0 Metres
4 Metres
3 Metres
3 Metres
6 Metres
2 Metres
9 Metres
1 Metres
12 Metres
Unit Size
Max KW Unit:
3.5KW
Unit Type:
Mini split
Note: The MicroBlue can be mounted in any orientation up to 2 Metres away from the air-conditioning unit. We recommend mounting the pump inside the ceiling cavity or ducting kit for a discreet fit.
Discharge Pipe
Vertical (V):
Horizontal (H):
16 Feet
0 Feet
13 Feet
9 Feet
9 Feet
20 Feet
6 Feet
30 Feet
3 Feet
40 Feet
Unit Size
Max KW Unit:
18000 BTU
Unit Type:
Mini split
Note: The MicroBlue can be mounted in any orientation up to 6 Feet away from the air-conditioning unit. We recommend mounting the pump inside the ceiling cavity or ducting kit for a discreet fit.
| Pump purchasing options | Part No. | Available in |
|---|---|---|
| MicroBLUE® + RESERVOIR (HLA) | X86-001 | UK, EU, ROW |
| MicroBLUE® + RESERVOIR (FSA) | X86-002 | UK, EU, ROW |
| MicroBLUE® + RESERVOIR (HLA) | X86-003 | Americas |
| MicroBLUE® + slim fascia KIT & reservoir | X86-011 | americas |
| MicroBLUE® + DUCTING KIT (IVORY) | X86-507 | UK, EU, ROW |
| MicroBLUE® + Ducting Kit (White) | X86-508 | UK, EU, ROW |
Alarm differences
FSA– Fail safe alarm, a volt free relay designed to switch the AC unit off, but leaves the pump running continuously when the condensate reaches a critical point in the reservoir.
HLA– High Level Audio is an integral audio and visual alarm. When the condensate is at a critical point with-in the reservoir, the diagnostic light in the pump will switch from green and will start to flash red with a 2 beep warning every minute. The pump will continue to operate while in alarm mode.
This mark indicates that our motors comply with UK regulations and meet the required health, safety, and environmental protection standards for products sold in Great Britain (England, Scotland, and Wales). For details, visit our compliance website here.
This mark signifies that our motors comply with CE requirements, confirming they meet essential health, safety, and environmental protection standards for products sold within the European Economic Area (EEA). For more information, visit our compliance website here.
Plenum spaces circulate air in buildings, often for HVAC systems. “Plenum-rated” materials limit smoke and toxic fumes in a fire, helping prevent their spread through the building. Visit compliance website here.
This mark indicates that our motors have been tested and meets safety standards in both the United States (UR) and Canada (cUR). Visit compliance website here.
Unique features
CONDENSENSE™ RESERVOIR
No more stuck float switches and regular reservoir maintenance. CondenSense™ technology uses advanced electronic sensing to intelligently detect the presence and precise level of condensate within the reservoir. This data-driven approach to condensate management enables real-time control of the MicroBlue’s operation, adjusting its performance dynamically to match the exact rate of condensate produced.
ADAPTIVE EFFICIENCY
The MicroBlue®’s Adaptive Efficiency, is powered by its advanced soft start technology and variable speed control. This allows the pump to adjust seamlessly to fluctuating condensate levels, ensuring optimal performance without unnecessary energy consumption. By reducing sudden surges in operation and running only as needed, the MicroBlue® not only extends its lifespan but also promotes energy efficiency. Find out more about the CondenSense™ Reservoir here.
PERFORMANCE IN SILENCE
Performing at its peak, the MicroBlue operates at just 17 dB(A), ensuring whisper-quiet performance. Its anti-vibration mounting bracket and rubberised edging minimise vibrations, making it ideal for noise-sensitive spaces like bedrooms, libraries, offices, and hospitals. With ultra-low sound and a vibration-free design, it delivers discreet, reliable operation without disruption.
TRUSTED RELIABILITY
The MicroBlue® was the first in its class to come with a market leading 3-year warranty—proof of the confidence we have in its patented, ultra-reliable pumping technology.
Every MicroBlue® pump is precision-engineered and rigorously tested at our state of the art manufacturing facility meeting or exceed ISO9001 standards. From material selection to final inspection, quality is built into every step.
Gyork ™ Technology EXPLAINED
VALVELESS TECHNOLOGY
GyroK™ pumping technology behaves like our proven Rotary Diaphragm technology—miniaturised and rotated 90 degrees on its side. This unique orientation introduces a rocking motion during rotation, delivering impressive head and lift performances for its size. By using a rotational gyroscopic diaphragm to move fluids without valves, it minimises clogging and maintenance. Its compact, design ensures steady, continuous flow, which effectively prevents sediment build-up. GyroK™ offers exceptional reliability for basic, daily condensate removal.
Product architecture has changed since the creation of this video – technology and performance remains the same.
Related Products
MICROBLUE + DUCTING
| Max Flow: | 5 L/HOUR (1.3 G/HOUR) |
| Max Head: | 5 M (16 FT) |
| Max Lift: | 2 M (6FT) |
| Sound: | 17 dB(A) |
| Unit: | 3.5 KW (18000 BTU) |
Available in UK & EU
MICROBLUE + FASCIA
| Max Flow: | 5 L/HOUR (1.3 G/HOUR) |
| Max Head: | 5 M (16 FT) |
| Max Lift: | 2 M (6FT) |
| Sound: | 17 dB(A) |
| Unit: | 3.5 KW (18000 BTU) |
Available in USA only
| Max Flow: | 8 L/MIN (2.1 G/HOUR) |
| Max Head: | 8 M (26 FT) |
| Max Lift: | 5 M (16FT) |
| Sound: | 21 dB(A) |
| Unit: | 3.5 – 8.0 KW (18000 BTU) |
AVAILABLE IN: UK, EU &
MINIBLUE
| Max Flow: | 8 L/HOUR (2.1 G/HOUR) |
| Max Head: | 8 M (26 FT) |
| Max Lift: | 5 M (16FT) |
| Sound: | 21 dB(A) |
| Unit: | 3.5 – 8.0 KW (18000 BTU) |
Available in UK & EU






UK, EU, ROW
Americas