ArctikBlue® V2

Reliable condensate drainage for dairy cabinets with V2 intelligence

Built with reliability in mind, the ArctikBlue® V2 delivers performance in a robust stainless steel tray, with a gravity-fed drainage channel and integrated CondenSense® technology.

Pump Overview
  • OrbiFlo® technology
  • Dual voltage: 115-230v – 50/60Hz
  • Alarm: Volt free, audio and LED
  • Integrated with CondenSense® detection – X88-858
  • Use for commercial supermarket fridges
  • Alternative solution to central vacuum systems.
  • Download datasheet here
ArctikBlue V2 Delivers
  • Automatic self-priming and run-dry tolerance with soft start
    activation.
  • CondenSense® intelligent flow adjustment with a condensate cycle memory for maximum efficiency.
  • Compatible with signalling with most leading case controllers.
  • Fluted drainage channel helps prevent bio-film build-up and condensate stagnation.
  • Swap-out pump kits available for easy preventative maintenance
Group 11930
Select measurement
Metric
Imperial
Performance

Max Flow:

50 L/Hour

Max Head:

20 Metres

Max Lift (N/A):

7 Metres

Volume level (Low flow):

19 dB(A)

Volume level (High level):

21 dB(A)

Alarm Type:

Volt free, Audio & LED

Unit size

Max A/C KW:

50 KW

Consumption (Rated)

Voltage:

115-230V

Frequency:

50/60Hz

Draw (A):

0.03 (115V), 0.06 (240V)

Power (W):

5.5W

Power (VA):

5.7VA

Power Factor:

0.96

IP Rating:

IPX4

Product sizing (L x W x H)

Dimensions:

337 x 457 x 65mm

Weight:

4.2 kg

Inlet:

40mm ID push fit

Outlet:

9.5mm, 12.7mm OD barbed

Alarm lead and power cable:

2 Metres

Tank capacity:

4.1 Litres

Pump on/off:

330ml

Alarm on vol:

3600ml

Performance

Max Flow:

13.2 G/Hour

Max Head:

66.5 Feet

Max Lift (N/A):

23 Feet

Volume level (Low flow):

19 dB(A)

Volume level (High flow):

21 dB(A)

Alarm Type:

Volt free, Audio & LED​

Unit size

Max A/C BTU:

170,000 BTU

Consumption (Rated)

Voltage:

115-230V

Frequency:

50/60Hz

Draw (A):

0.13 (115V), 0.06 (230V)

Power (W):

5.5W

Power (VA):

5.7VA

Power Factor:

0.96

IP Rating:

IPX4

Sizing (L x W x H)

Dimensions:

13.3 x 18.0 x 2.56"

Weight:

22.5 oz

Inlet:

1.57" ID push fit

Outlet:

3/8", 1/2" Barbed

Alarm Lead and power cable:

6.5 Feet

Tank capacity:

1.08 Gallons

Pump on/off:

11.16 fl oz

Alarm on vol:

121.7 fl oz

Tested performance

The graph presents flow, head, and lift performance for the ArctikBlue V2 operating conditions, showing how each parameter which may vary depending on conditions and thickness of liquid.

Regularly trusted by engineers worldwide, the ArctikBlue V2 has earned a reputation for durability and reliability, significantly reducing the need for call-outs and regular maintenance.

All pumps must be installed by a qualified engineer/ HVACR Technician

Tested performance

The graph presents flow, head, and lift performance for the ArctikBlue V2 operating conditions, showing how each parameter which may vary depending on conditions and thickness of liquid.

Regularly trusted by engineers worldwide, the ArctikBlue V2 has earned a reputation for durability and reliability, significantly reducing the need for call-outs and regular maintenance.

All pumps must be installed by a qualified engineer/ HVACR Technician

Discharge Pipe

Vertical (V):

Horizontal (H):

20 Metres

0 Metres

17 Metres

9 Metres

14 Metres

18 Metres

11 Metres

27 Metres

9 Metres

33 Metres

6 Metres

42 Metres

3 Metres

51 Metres

0 Metres

60 Metres

Unit Size

Max KW Unit:

50KW

Unit Type:

Fridge

Note: The ArctikBlue V2’s maximum head (20m) is NOT reduced or effected by suction lift (7m). Once installed, suction lift and discharge head should be considered independently. Ideal for small air conditioning units.

For each metre not used on vertical head you can run 3m on the horizontal.

  • A heavy load on the pump will reduce the flow rate over greater distances.
  • Performance is for guide only. It is the ultimate responsibility of the end user to ensure pump is fit for purpose.
Discharge Pipe

Vertical (V):

Horizontal (H):

65.5 Feet

0 Feet

56 Feet

30 Feet

46 Feet

60 Feet

36 Feet

88.5 Feet

30 Feet

108 Feet

20 Feet

138 Feet

10 Feet

168 Feet

0 Feet

200 Feet

Unit Size

Max KW Unit:

170,000 BTU

Unit Type:

Fridge

Note: The ArctikBlue V2’s maximum head (66.5ft) is NOT reduced or effected by suction lift (23ft). Once installed, suction lift and discharge head should be considered independently. Ideal for small air conditioning units.

For each metre not used on vertical head you can run 10FT on the horizontal.

  • A heavy load on the pump will reduce the flow rate over greater distances.
  • Performance is for guide only. It is the ultimate responsibility of the end user to ensure pump is fit for purpose.
Pump purchasing options Part No. Available in
ArctikBlue® V2 with CondenSense® detection X88-858 Americas    Americas
ArctikBlue® V2 Swap-out kit X88-860 Americas    Americas
New alarm system with dynamic monitoring

The FSA (Fail Safe Alarm) and HLA (High Level Audio) functions have been combined into a single, enhanced alarm system package. V2 models now incorporate both features along with an LED indicator as standard, delivering a more streamlined and comprehensive solution.

This product has been independently tested and certified by ETL (Electrical Testing Laboratories) Intertek (part of Intertek an independent lab) to meet recognised safety standards. Visit compliance website here.

Plenum spaces circulate air in buildings, often for HVAC systems. “Plenum-rated” materials limit smoke and toxic fumes in a fire, helping prevent their spread through the building. 

V2 NEW INTELLIGENT FEATURES

Seamless, thick-gauge steel tray

Using thick-gauge stainless steel, the seamless tray is built for the demands of commercial refrigeration. Its robust construction ensures long-term durability, while universal fridge fittings simplify installation.

Condensense icon BDP UK

CondenSense® integration

Updated sensor technology with an integrated CS2 microchip provides automatic flow adjustment and smooth pump start-up for improved efficiency. The pump and sensor also learn from previous duty cycles to optimise performance.

Discreet, low profile

With a 65mm low-profile design and operation from as low as 19 dB(A), the ArctikBlue V2 can be installed discreetly beneath refrigeration cabinets without taking up unnecessary floor space or creating unwanted noise.

OrbiFlo® Technology

  • Self-priming, valve-free operation
  • Excellent dry-run tolerance
  • Clog-resistant design
  • Handles bio-films and suspended solids
  • Smooth, pulsation-free flow
  • Reinforced membrane with robust spine
  • Operates in any orientation

V2 SERIES Features explained

See how the V2 delivers intelligent condensate removal solutions for multiple industries

Related Products

PRODUCT DOWNLOADS

Yes. Please redirect me No. Continue here
Scroll to Top