V2 SERIES
MaxiBlue® V2
Slim Fascia Kit (SFK) for quick, discreet, hassle free installation with built-in V2 intelligence
Ensuring efficient, dependable operation for domestic and commercial air conditioning systems. Backed by the trusted durability of the BlueDiamond® V2 Series and 3 year warranty.
Pump Overview
- OrbiFlo® technology
- Dual voltage: 115-230v – 50/60Hz
- Alarm: Volt free, audio and LED
- Comes with CondenSense® reservoir sensor – X88-011
- Use for fan coil units
- Mid-rangedomestic and commercial spaces.
- Download datasheethere
MaxiBlue V2 Delivers
- Automatic self priming and run dry tolerance.
- Refined OrbiFlo® technology to prevent bio-film build-up.
- CondenSense® integration for intelligent, automatic flow adjustment.
- Records regular condensate levels for future removal cycles.
- Soft start sequencing ensures smooth, quiet system activation.
- Pre-assembled kit for simple plug-and-play set-up
Performance
Max Flow:
14 L/Hour
Max Head:
8 Metres
Max Lift (N/A):
8 Metres
Volume level (Low flow):
19 dB(A)
Volume level (High level):
21 dB(A)
Alarm Type:
Volt free, Audio & LED
Unit size
Max A/C KW:
14 KW
Fascia kit colour
White:
RAL9003
Consumption (Rated)
Voltage:
115-230V
Frequency:
50/60Hz
Draw (A):
0.03 (115V), 0.06 (240V)
Power (W):
5.5W
Power (VA):
5.7VA
Power Factor:
0.96
IP Rating:
IPX4
Product sizing (L x W x H)
Fascia dimensions:
310 x 66 x 89mm
Weight:
950g
Inlet:
8mm Straight
Outlet:
8mm Straight
Alarm lead and power cable:
2 Metres
Pump:
148 x 57 x 74mm
Reservoir:
92 x 32 x 38mm
Reservoir lead length:
40cm
+ Extension lead (in box):
2 Metres (2.4m Total)
Performance
Max Flow:
3.7 G/Hour
Max Head:
26 Feet
Max Lift (N/A):
26 Feet
Volume level (Low flow):
19 dB(A)
Volume level (High flow):
21 dB(A)
Alarm Type:
Volt free, Audio & LED
Unit size
Max A/C BTU:
48,000 BTU
Fascia kit colour
White:
RAL9003
Consumption (Rated)
Voltage:
115-230V
Frequency:
50/60Hz
Draw (A):
0.13 (115V), 0.06 (230V)
Power (W):
5.5W
Power (VA):
5.7VA
Power Factor:
0.96
IP Rating:
IPX4
Sizing (L x W x H)
Fascia dimensions:
12.2 x 2.6 x 3.5"
Weight:
22.5 oz
Inlet:
1/4 Inch Straight
Outlet:
1/4 Inch Straight
Alarm Lead and power cable:
6.5 Feet
Pump:
5.8 x 2.2 x 2.9"
Reservoir:
4.0 x 1.2 x 1.5"
Reservoir lead length:
16.0"
+ Extension lead (in box):
6.5ft (7.8ft total)
Performance
Max Flow:
3.7 G/Hour
Max Head:
26 Feet
Max Lift (N/A):
26 Feet
Volume level (Low flow):
19 dB(A)
Volume level (High flow):
21 dB(A)
Alarm Type:
Volt free, Audio & LED
Unit size
Max A/C BTU:
48,000 BTU
Consumption (Rated)
Voltage:
115-230V
Frequency:
50/60Hz
Draw (A):
0.13 (115V), 0.06 (230V)
Power (W):
5.5W
Power (VA):
5.7VA
Power Factor:
0.96
IP Rating:
IPX4
Sizing (L x W x H)
Fascia dimensions:
12.2 x 2.6 x 3.5"
Weight:
33.5 oz
Inlet:
1/4" Straight
Outlet:
1/4" Straight
Alarm Lead and power cable:
6.5 Feet
Pump:
5.8 x 2.2 x 2.9"
Reservoir:
4.0 x 1.2 x 1.5"
Reservoir lead length:
16.0"
+ Extension lead (in box):
6.5ft (7.8ft total)
Tested performance
The graph presents flow, head, and lift performance for the MaxiBlue V2 operating conditions, showing how each parameter which may vary depending on conditions and thickness of liquid.
Regularly trusted by engineers worldwide, the Maxiblue V2 has earned a reputation for durability and reliability, significantly reducing the need for call-outs and regular maintenance.
All pumps must be installed by a qualified engineer/ HVACR Technician
Tested performance
The graph presents flow, head, and lift performance for the MaxiBlue V2 operating conditions, showing how each parameter which may vary depending on conditions and thickness of liquid.
Regularly trusted by engineers worldwide, the Maxiblue V2 has earned a reputation for durability and reliability, significantly reducing the need for call-outs and regular maintenance.
All pumps must be installed by a qualified engineer/ HVACR Technician
Tested performance
The graph presents flow, head, and lift performance for the MaxiBlue V2 operating conditions, showing how each parameter which may vary depending on conditions and thickness of liquid.
Regularly trusted by engineers worldwide, the Maxiblue V2 has earned a reputation for durability and reliability, significantly reducing the need for call-outs and regular maintenance.
All pumps must be installed by a qualified engineer/ HVACR Technician
Discharge Pipe
Vertical (V):
Horizontal (H):
8 Metres
0 Metres
7 Metres
3 Metres
6 Metres
6 Metres
5 Metres
9 Metres
4 Metres
12 Metres
3 Metres
15 Metres
2 Metres
18 Metres
1 Metres
21 Metres
Unit Size
Max KW Unit:
14KW
Unit Type:
Mini split
Note: The MaxiBlue V2’s maximum head (8m) is NOT reduced or effected by suction lift (8m). Once installed, suction lift and discharge head should be considered independently. Ideal for small air conditioning units.
For each metre not used on vertical head you can run 3m on the horizontal.
- A heavy load on the pump will reduce the flow rate over greater distances.
- Performance is for guide only. It is the ultimate responsibility of the end user to ensure pump is fit for purpose.
Discharge Pipe
Vertical (V):
Horizontal (H):
25 Feet
0 Feet
22 Feet
9 Feet
20 Feet
20 Feet
16 Feet
30 Feet
13 Feet
40 Feet
9 Feet
50 Feet
6 Feet
60 Feet
3 Feet
70 Feet
Unit Size
Max KW Unit:
48,000 BTU
Unit Type:
Mini split
Note: The MiniBlue V2’s maximum head (25FT) is NOT reduced or effected by suction lift (25FT). Once installed, suction lift and discharge head should be considered independently. Ideal for small air conditioning units.
For each metre not used on vertical head you can run 10FT on the horizontal.
- A heavy load on the pump will reduce the flow rate over greater distances.
- Performance is for guide only. It is the ultimate responsibility of the end user to ensure pump is fit for purpose.
Discharge Pipe
Vertical (V):
Horizontal (H):
25 Feet
0 Feet
22 Feet
9 Feet
20 Feet
20 Feet
16 Feet
30 Feet
13 Feet
40 Feet
9 Feet
50 Feet
6 Feet
60 Feet
3 Feet
70 Feet
Unit Size
Max KW Unit:
48,000 BTU
Unit Type:
Mini split
Note: The MiniBlue V2’s maximum head (25FT) is NOT reduced or effected by suction lift (25FT). Once installed, suction lift and discharge head should be considered independently. Ideal for small air conditioning units.
For each metre not used on vertical head you can run 10FT on the horizontal.
- A heavy load on the pump will reduce the flow rate over greater distances.
- Performance is for guide only. It is the ultimate responsibility of the end user to ensure pump is fit for purpose.
| Pump purchasing options | Part No. | Available in |
|---|---|---|
| MaxiBlue® V2 Slim fascia kit with CondenSense® reservoir | X88-011 |
Americas
|
New alarm system with dynamic monitoring
The FSA (Fail Safe Alarm) and HLA (High Level Audio) functions have been combined into a single, enhanced alarm system package. V2 models now incorporate both features along with an LED indicator as standard, delivering a more streamlined and comprehensive solution.
This product has been independently tested and certified by ETL (Electrical Testing Laboratories) Intertek (part of Intertek an independent lab) to meet recognised safety standards. Visit compliance website here.
Plenum spaces circulate air in buildings, often for HVAC systems. “Plenum-rated” materials limit smoke and toxic fumes in a fire, helping prevent their spread through the building.
V2 NEW INTELLIGENT FEATURES
Plug and play set-up
The slim fascia kit comes pre-assembled for quick, hassle-free installation. Experience intelligent, efficient and powerful performance in a discreet, compact package that’s ready to install straight out of the box.
CondenSense®
Compact sensor technology with an intergrated CS2 microchip delivers automatic flow adjustment, smooth startup, and quick installation.
Quiet by design
Anti-vibration feet and intelligent soft start variable flow control deliver powerful, ultra-quiet performance with sound levels as low as19 dB(A).
OrbiFlo® Technology
- Self-priming, valve-free operation
- Excellent dry-run tolerance
- Clog-resistant design
- Handles bio-films and suspended solids
- Smooth, pulsation-free flow
- Reinforced membrane with robust spine
- Operates in any orientation
V2 SERIES Features explained
See how the V2 delivers intelligent condensate removal solutions for multiple industries
Related Products
Part of the V2 Series - Comes with
CondenSense® Reservoir Sensor
Part No : X88-721
Now with V2 features - Comes with:
Slim Fascia kit with CondenSense® Reservoir Sensor(FSA Alarm)
Part No : X86-011
Part of the V2 Series - Comes with
CondenSense® Reservoir Sensor
Part No : X88-835
PRODUCT DOWNLOADS
CAD Model
Warranty
Keep track of your pumps
history and installation date for future reference (Optional).




Americas